Thermal Bridges Breakdown
Detailed junction lengths and heat loss calculations
Total Junctions
0
Total Heat Loss
0.000
W/K
Y-value (estimated)
NaN
Calculated by Elmhurst
| Junction | Type | Length (m) | Psi-value (W/mK) | Heat Loss (W/K) | f-factor | Actions |
|---|---|---|---|---|---|---|
| TOTAL | 0.000 W/K | |||||
💡 How to use these values:
- Go to Elmhurst → Thermal Bridging
- Set Method: "Calculate Bridges"
- Add each junction with its length and psi-value
- Elmhurst will calculate the final Y-value automatically
Common thermal bridge junctions in UK residential construction with accredited psi-values.
Above windows and doors
Length: Opening width + 300mm bearing
Steel/concrete lintels with perforated base plate. RCD: 0.03-0.05, Accredited: 0.10
Below windows, intermediate floor to external wall
Length: Opening width
Tile/stone/precast sills. RCD optimized: 0.04-0.06
Sides of windows and doors
Length: Opening height × 2 sides
Cavity closer required. RCD: 0.03-0.05, Accredited: 0.05
Building corners (convex)
Length: Storey height × corner count
NEGATIVE psi = thermal benefit. Detached: 4 corners, Semi: 2 corners
Roof to wall junction, insulation at ceiling
Length: Roof perimeter
For cold pitched roofs with loft insulation
Roof to wall junction, insulation at rafter
Length: Roof perimeter
For warm roofs or rooms in roof
Roof to party wall junction
Length: Party wall length at eaves
Only for semi-detached and terraced properties
Floor to wall junction
Length: Ground floor perimeter
Varies by floor insulation. RCD: 0.08-0.12, Default: 0.15
First floor to external wall
Length: First floor perimeter
Only for multi-storey. RCD: 0.07, Accredited: 0.13
Sloping roof edge at gable
Length: Roof slope length × gable count
Typically 2 gables for pitched roof. RCD: 0.05, Default: 0.08
Flat roof to upstand parapet
Length: Parapet length
High heat loss area. Requires good insulation continuity
🎯 RCD Optimization
RCD (Recognised Construction Details) provide BRE-certified lower psi-values for standard brick/block constructions. Typical improvements: 20-30% reduction in thermal bridging heat loss.