Thermal Bridges Breakdown

Detailed junction lengths and heat loss calculations

Total Junctions

0

Total Heat Loss

0.000

W/K

Y-value (estimated)

NaN

Calculated by Elmhurst

Thermal Bridge Junctions
JunctionTypeLength (m)Psi-value (W/mK)Heat Loss (W/K)f-factorActions
TOTAL0.000 W/K

💡 How to use these values:

  1. Go to Elmhurst → Thermal Bridging
  2. Set Method: "Calculate Bridges"
  3. Add each junction with its length and psi-value
  4. Elmhurst will calculate the final Y-value automatically
High heat loss (>1 W/K)
Medium heat loss (0.5-1 W/K)
📘 Junction Type Reference Guide

Common thermal bridge junctions in UK residential construction with accredited psi-values.

E2Lintels
ψ 0.03-0.10

Above windows and doors

Length: Opening width + 300mm bearing

Steel/concrete lintels with perforated base plate. RCD: 0.03-0.05, Accredited: 0.10

E3Sills
ψ 0.04-0.10

Below windows, intermediate floor to external wall

Length: Opening width

Tile/stone/precast sills. RCD optimized: 0.04-0.06

E5Jambs
ψ 0.04-0.08

Sides of windows and doors

Length: Opening height × 2 sides

Cavity closer required. RCD: 0.03-0.05, Accredited: 0.05

E6/E8External Corners
ψ -0.15

Building corners (convex)

Length: Storey height × corner count

NEGATIVE psi = thermal benefit. Detached: 4 corners, Semi: 2 corners

E21Eaves (Ceiling Insulation)
ψ 0.06

Roof to wall junction, insulation at ceiling

Length: Roof perimeter

For cold pitched roofs with loft insulation

E22Eaves (Rafter Insulation)
ψ 0.04

Roof to wall junction, insulation at rafter

Length: Roof perimeter

For warm roofs or rooms in roof

E23Party Wall Eaves
ψ 0.04

Roof to party wall junction

Length: Party wall length at eaves

Only for semi-detached and terraced properties

P1Ground Floor Perimeter
ψ 0.08-0.16

Floor to wall junction

Length: Ground floor perimeter

Varies by floor insulation. RCD: 0.08-0.12, Default: 0.15

P8Intermediate Floor
ψ 0.07-0.13

First floor to external wall

Length: First floor perimeter

Only for multi-storey. RCD: 0.07, Accredited: 0.13

R1Roof Verge (Gable)
ψ 0.05-0.08

Sloping roof edge at gable

Length: Roof slope length × gable count

Typically 2 gables for pitched roof. RCD: 0.05, Default: 0.08

R6Flat Roof Parapet
ψ 0.25-0.40

Flat roof to upstand parapet

Length: Parapet length

High heat loss area. Requires good insulation continuity

🎯 RCD Optimization

RCD (Recognised Construction Details) provide BRE-certified lower psi-values for standard brick/block constructions. Typical improvements: 20-30% reduction in thermal bridging heat loss.

BRE Accredited Psi-Value Database